BOD = (DO_initial − DO_final) × dilution factor; COD via dichromate titration.
BOD
COD (Dichromate)
BOD = (DO initial − DO final) × dilution factor (dilution factor = bottle volume ÷ sample volume). COD = (blank − sample titrant mL) × N × 8000 ÷ sample mL, with the titrant being ferrous ammonium sulfate (standard methods, closed/open reflux dichromate).
How it works
BOD and COD both quantify how much oxygen a water sample will consume, by two different routes. BOD tracks the dissolved oxygen that microbes actually use over an incubation, classically five days in the dark at 20 °C, so it measures the biodegradable fraction. COD oxidises the sample chemically with dichromate and captures organics the bacteria will not touch. COD returns in about three hours; BOD takes five days, which is why most plants run both.
BOD₅ (mg/L) = (DO_initial − DO_final) × Dilution factor COD (mg/L) = (V_blank − V_sample) × N × 8000 / mL of sample
DO_initial, DO_finaldissolved oxygen in the bottle on day 0 and day 5, mg/LDilution factortotal bottle volume ÷ volume of sample in it (5 mL in a 300 mL bottle gives 60)V_blank, V_samplemL of ferrous ammonium sulphate titrant used on the reagent blank and on the digested sampleNnormality of the FAS titrant8000milligrams of oxygen per equivalent (8 g/eq × 1000 mg/g)
- Dilution factor: 300 / 5 = 60
- Oxygen depletion: 8.4 − 3.1 = 5.3 mg/L
- BOD₅ = 5.3 × 60 = 318 mg/L
- COD = (10.0 − 7.0) × 0.25 × 8000 / 10 = 600 mg/L
- Ratio: 600 / 318 = 1.89
- A dilution only counts if it lands inside the working window: at least 2.0 mg/L of oxygen consumed and at least 1.0 mg/L still remaining on day 5. Outside that, the bottle either ran out of oxygen or barely moved, and the number is not defensible. Labs set up three or four dilutions per sample precisely so that at least one qualifies.
- COD exceeds BOD for effectively every real sample, and the ratio is the diagnostic. Raw municipal sewage typically runs 1.5 to 2.5, and 1.89 above sits in the middle of it. Ratios climbing past about 4 point to industrial input or an inhibitory load and warn you that a biological stage alone will not meet consent.
- Nitrifying bacteria begin drawing oxygen in some samples before day 5, inflating the result with demand that has nothing to do with carbon. Adding a nitrification inhibitor and reporting CBOD is standard for nitrified effluent, and mixing CBOD and BOD figures across a dataset produces a trend that is not real.
Most Searched Today
Frequently Asked Questions
Bod Cod Calc runs right in the browser tab you already have open. No install, no account, no cost.
Bod Cod Calc follows the standard method used in textbooks and technical references for this calculation, and we show the formula or approach on the page itself so you can check the working rather than trust a black box. Found an edge case that breaks it? Use the feedback button in the bottom-right corner.